PARTICULATE MATTER IN INDOOR AIR OF A BAKERY

Authors

  • Caca Crnjak Autor
  • Dragan Adamović Departman za Inženjerstvo zaštite životne sredine i zaštite na radu Autor

DOI:

https://doi.org/10.24867/13HZ03Crnjak

Keywords:

Particulate Matter, Air Pollution, Safety at Work

Abstract

This paper presents the air's measurement and analysis in a bakery in Novi Sad at four locations within the production process, in the production premises, at the point of sale, warehouse of finished products, and outside. The measurement was performed with air quality sensor analyzers for the period from 14.05.2020. to 31.05.2020, and the results were read every two minutes. The parameters measured were temperature, humidity, pressure, and suspended particles from the categories: PM1, PM2.5, and PM10. The obtained results indicate very frequent exceeding of the recommended limit values, which requires improvement of the production process to minimize particulate matter emissions and the use of personal protective equipment to prevent the development of occupational inhalation diseases.

References

[1] Zhang, H., Wang, Shuxiao, Hao, J., Wang, X., Wang, Shulan, Chai, F., Li, M., 2016. Air pollution and control action in Beijing. J. Clean. Prod. doi:10.1016/j.jclepro.2015.04.092
[2] Kelly, F.J., Fussell, J.C., 2012. Size, source and chemical composition as determinants of toxicity attributable to ambient particulate matter. Atmos. Environ. doi:10.1016/j.atmosenv.2012.06.039
[3] Bae, S., Hong, Y.C., 2018. Health effects of particulate matter. J. Korean Med. Assoc. doi:10.5124/jkma.2018.61.12.749
[4] https://www.irsst.qc.ca/media/documents/PubIRSST/RF-532.pdf (24.03.2021)

Published

2021-08-04

Issue

Section

Environment and Occupational Safety Engineering