FUEL TURBINE FLOW METER TESTING

Authors

  • Branka Sremački Autor

DOI:

https://doi.org/10.24867/03AM05Sremacki

Keywords:

turbinefuel flow meter, calibration process

Abstract

In this paper, theoretical and laboratory solutions of the calibration of the turbinefuel flow meter are given. The influence factors of the calibration process are also explained. The flow measurement systems was tasted. The measurement procedure is explained. Characteristics of used equipment are given and the test results are shown.

References

[1] Cvijanović S. Petar, Turbinska merila zapremine tečnosti, monografija.
[2] W. F. Z. LEE Chief Research Analyst, Central Research and Development Laboratory, Rockwell Manufacturing Company, Pittsburgh, Pa, A Study if Viscosity Effect anil Its Compensation on Turbine-Type Flowmeters.
[3] www.am.unze.ba/mt/2014/Begic.ppt
[4] http://www.super-lab.com/fajlovi-upload/brosura-metrolab-2018.pdf
[5] Bukurov, M., Mehanika fluida, knjiga prva, FTN izdavaštvo, Novi Sad, 2013.
[6] Rubin, M., Miller, R.W., and Fox, W.G. Driving Torques in a Theoretical Model of a Turbine Meter, Transactions of the ASME. Journal of Basic Engineering, Paper Number 64 - WA/FM-2, 1965.
[7] https://ftimeters.com/wp-content/uploads/2017/.../Universal-Calibrations-FT-Series.pdf viskoznost.

Published

2019-05-17