Skip to main navigation menu Skip to main content Skip to site footer

Pure energy technologies

Vol. 41 No. 07 (2026): Proceedings of the Faculty of Technical Sciences

Analysis and Optimization of a VRF System in a Residential Building Using the Bosch AirSelect Software Tool

  • Ksenija Lazić
  • Igor Mujan
DOI:
https://doi.org/10.24867/35UI02Lazic
Submitted
November 2, 2026
Published
2026-07-15

Abstract

The paper presents the analysis and optimization of a variable frequency (VRF) air conditioning system for a single-family residential building in Belgrade. Special emphasis is placed on the theoretical foundations of the dimensioning of freon pipelines, the importance of proper equipment selection and the application of software tools in the design process. The calculation and validation of the system were performed using the Bosch Air Select software, which enabled checking of capacity, pipeline length and height differences. The results of the analysis showed a slight overload of the outdoor unit, based on which optimization of the system was proposed by selecting a more powerful outdoor unit. The techno-economic analysis determined that the proposed solution provides greater reliability, more stable operation and improved energy efficiency of the system in long-term operation.

References

  1. [1] ASHRAE Handbook — HVAC Systems and Equipment. American Society of Heating, Refrigerating and Air-Conditioning Engineers; 2016.
  2. [2] Ma Z, Wang S. Variable Refrigerant Flow Systems: Design and Applications. Springer; 2015.
  3. [3] Kriner D. Air Conditioning: The Development of Modern HVAC Systems. Springer; 2012.
  4. [4] Bosch Climate Solutions. AirSelect Software Manual. Bosch Thermotechnik; 2022. Available from: https://www.bosch-thermotechnology.com
  5. [5] Bosch AirSelect. Available from: https://www.bosch-airselect.com/#/
  6. [6] Yau YH, Rajput UA, Badarudin A. A comprehensive review of variable refrigerant flow (VRF) and ventilation designs for thermal comfort in commercial buildings. J Therm Anal Calorim. 2024;149(5):1935-61.
  7. [7] Daikin Industries Ltd. VRV/VRF Technical Manual. 2021.
  8. [8] Pipe HPAR, Gas WE. Providing Fully Developed Flow for Waste Exhaust Gas at the Inlet Region of a Heat Pipe Air Recuperator. Global J Res Eng Civ Struct Eng. 2024;4(05).