CAVITATION DETECTION IN CENTRIFUGAL PUMPS USING VIBRO-DAGNOSTIC METHODS
DOI:
https://doi.org/10.24867/06AM04VucinicKeywords:
vibrations, vibration diagnostic, cavitation, centrifugal pumpsAbstract
Within the paper the procedure of experimental testing of the occurrence of cavitation on the example of one centrifugal pump in the pumping station „Liman" in Novi Sad is presented. The experiment comprised parallel measurement of the pump hydraulic parameters and vibrations at selected points on the pump casing. The concepts of cavitation and vibration diagnostics are explained and the procedure and test results are presented as well as the analysis of the results.
References
[1] Ташин, С. „Оптимални дијагностички пакет параметара за детекцију кавитацијских режима у центрифугалним пумпама“, докторски рад, Нови Сад, Факултет техничких наука, 2016. год.
[2] Вуковић, Ж., Халкијевић, И. „Кавитација у цен-трифугалним црпкама“, Грађевинар 63-1, 2011.г.
[3] Hergt P., Nicklas, A., Mollenkopf, G., Brodersen, S. „The suction performance of centrifugal pumps possibilities and limits of improvements“. Proceedings of the 13th International Pump Users Symposium, Houston, p. 13-25, 1996.
[2] Вуковић, Ж., Халкијевић, И. „Кавитација у цен-трифугалним црпкама“, Грађевинар 63-1, 2011.г.
[3] Hergt P., Nicklas, A., Mollenkopf, G., Brodersen, S. „The suction performance of centrifugal pumps possibilities and limits of improvements“. Proceedings of the 13th International Pump Users Symposium, Houston, p. 13-25, 1996.
Downloads
Published
2019-12-16
Issue
Section
Mechanical Engineering