Skip to main navigation menu Skip to main content Skip to site footer

Mechanical Engineering

Vol. 35 No. 01 (2020): Proceedings of the Faculty of Technical Sciences

CAVITATION DETECTION IN CENTRIFUGAL PUMPS USING VIBRO-DAGNOSTIC METHODS

  • Радивојка Вучинић
DOI:
https://doi.org/10.24867/06AM04Vucinic
Submitted
December 16, 2019
Published
2019-12-16

Abstract

Within the paper the procedure of experimental testing of the occurrence of cavitation on the example of one centrifugal pump in the pumping station „Liman" in Novi Sad is presented. The experiment comprised parallel measurement of the pump hydraulic parameters and vibra­tions at selected points on the pump casing. The concepts of cavitation and vibration diagnostics are explained and the procedure and test results are presented as well as the analysis of the results.

References

[1] Ташин, С. „Оптимални дијагностички пакет параметара за детекцију кавитацијских режима у центрифугалним пумпама“, докторски рад, Нови Сад, Факултет техничких наука, 2016. год.
[2] Вуковић, Ж., Халкијевић, И. „Кавитација у цен-трифугалним црпкама“, Грађевинар 63-1, 2011.г.
[3] Hergt P., Nicklas, A., Mollenkopf, G., Brodersen, S. „The suction performance of centrifugal pumps possibilities and limits of improvements“. Proceedings of the 13th International Pump Users Symposium, Houston, p. 13-25, 1996.